BMS CAN Current Sensor

 149,00 Ex. VAT

Data sheets

We have “data sheets” available for more and more products. Click the button below. If not (yet) available contact us and we will help you.

The EMUS CAN current sensor is a current sensor with high accuracy and has the advantage of being fully CAN controlled, so it can easily be placed at any position in a High Voltge system. In addition, the current sensor has 1 or 3 high voltage measurements, for example suitable for a pre-charge voltage measurement or extra measurements behind for example DC (CCS) contactors.

  • Nominal current range ±300A
  • Maximum peak current (1min) up to ±400A (in development 1000A version)
  • Maximum peak current (15sec) up to ±650A
  • Resolution 1mA
  • Typical current measurement error ±0.35%
  • Maximum offset 15mA
  • Maximum safe input voltage ±1500V
  • Isolation voltage** 850VDC
  • CAN speed 250kbit/s or 500kbit/s
  • Default communication period 100ms
  • Supply voltage 6 – 70VDC
  • Current consumption sleep mode 68μA@12VDC / 44μA@24VDC
  • Wake up GPI voltage input 6 – 70VDC
  • Recommended ambient temperature usage range* -30 to +55ºC
  • Typical voltage measurement error*** ±0.1% + 2 digits
  • IP rating IP42
  • Dimensions: 86.5x84x17.2 mm
  • Mounting holes: M8.3 (version CS030A-300A-(P1/N1)-X-X)

 149,00 Ex. VAT